Author |
Topic: "SYS" Box with Exclamation Point (Read 1606 times) |
|
MidiBilly
New Member

 I love YaBB 1 Gold!
Posts: 1
|
 |
"SYS" Box with Exclamation Point
« on: Nov 6th, 2001, 5:29pm » |
Quote Modify
|
Hi, I'm attempting to send a SYSEX file from my PC to my Korg A3 signal processor. I get as far as configuring the send, but it seems as though the process halts after a second or two with a warning box with the word "sys" and an exclamation point picture. I notice that my unit does receive the initial sysex file transfer command since it successfully goes into "receive" mode. However, since the transfer is not completed, it stays in the receive mode. All I can do is cancel the transfer. Upon reviewing the processor unit, I notice nothing is changed. Any ideas/help? Thanks!
|
|
IP Logged |
|
|
|
Jamie OConnell
Administrator
    


Gender: 
Posts: 2027
|
 |
Re: "SYS" Box with Exclamation Point
« Reply #1 on: Nov 6th, 2001, 10:01pm » |
Quote Modify
|
What MIDI interface are you using to transfer the data? Is it an ISA, PCI, or USB device? Check the buffer configuration: recommended is 16 buffers, each 256 bytes in size, for both input and output. Also check [x] Delay after F7 [ 60 ] Milliseconds and Delay [ 60 ] Milliseconds Between Buffers. If it starts working OK, you can reduce the delays.
|
|
IP Logged |
--Jamie Music is its own reward.
|
|
|
|