Author |
Topic: problem... (Read 745 times) |
|
Ruh
New Member

 MIDI-OX Rules!

Posts: 2
|
at first i want to say hallo to all members and i hope you understand my terrible english, i learned it at school a long time ago. the problem: i downloaded the midiox software especially to transmit mididumps from my korg electribe r mkII.it is no problem to send the dump to the computer.but when i try to send the dump back to the korg, i get the followimg message: "sysex output devices: der anschluss ist mit der datenausgabe belegt.warten sie,bis die daten übertragen wurden" i try to translate: "sysex output devices: the connection is taken with the data distribution. wait, until the data is broadcast." what is wrong?i think i did everything right.i choosed the right midichannel and all the connections are ok.the electribe also shows me that it receives dates from the computer,but only a few secondes until the message is showing me. thanks for your help!
|
|
IP Logged |
|
|
|
Jamie OConnell
Administrator
    


Gender: 
Posts: 2027
|
 |
Re: problem...
« Reply #1 on: Oct 22nd, 2005, 7:46pm » |
Quote Modify
|
In the MIDI-OX SysEx View, open SysEx | Configure... and make the following setting: [X] Delay after F7 [ 120 ] Milliseconds. Then try the transfer again.
|
|
IP Logged |
--Jamie Music is its own reward.
|
|
|
Ruh
New Member

 MIDI-OX Rules!

Posts: 2
|
 |
Re: problem...
« Reply #2 on: Oct 23rd, 2005, 8:38am » |
Quote Modify
|
thanks!that was the problem.now it works really good.
|
|
IP Logged |
|
|
|
|