MIDI-OX User Forum (http://www.midiox.com/cgi-bin/yabb/YaBB.pl)
MIDI-OX >> Mapping Questions >> two controller = the same values = problems
(Message started by: Pseudomonas_Torx on Dec 14th, 2010, 7:17pm)

Title: two controller = the same values = problems
Post by Pseudomonas_Torx on Dec 14th, 2010, 7:17pm
Hello all.
First excuse my English please. I work with Google translator. I only speak very little English.
To my problem.
I have two controllers (APC20 and MS20), which I would like to take together in Ableton Live. Now when I assign a trigger pad on the APC20, has itself automatically on the MS20-keyboard parameters.
How can I change with "MidiOX" the CC data from the APC. Or change the midi channels.
Since "MidiOX" to be English is hard for me to understand it all.
It would be really cool if one of you agreed to me step by step, explaining everything again.
first thank you in advance
Greetings

Title: Re: two controller = the same values = problems
Post by Peter L Jones on Dec 15th, 2010, 2:20am
You need to provide more information.

How are the two devices connected to your computer?

If they connect on the same MIDI port, then nothing will be able to tell a message from one device from a message from the other device -- MIDI messages do no contain details of where they have come from.

If they are on different MIDI ports (e.g. separate USB connectors), then you can assign a Data Map to one of the connections.

You will need to install both MIDI Ox and MIDI Yoke and have a set up like this for one device:

[Device MIDI Out]->[PC MIDI In]->{MIDI Ox}
{MIDI Ox}->[MIDI Yoke Out 1]
[MIDI Yoke In 1]->{Ableton Live}

Title: Re: two controller = the same values = problems
Post by Sir Raven on Dec 16th, 2010, 5:26am
If the forum members don't mind, we'll to this in german.

@Pseudomonas_Torx
Was genau willst Du wissen?
Die verschiedenen MIDI-Ports kannst Du über Optionen/MIDI Devices zuweisen. Da Du beschreibst, dass beide Geräte angesteuert werden hast Du das wohl schon durchgeführt.
Wenn ich Dich korrekt verstanden habe, ist Dein Problem, dass die MIDI-Daten immer automatisch an das jeweils andere Gerät (also den jeweils anderen MIDI-Port) durchgereicht werden. Ist das soweit korrekt?

Title: Re: two controller = the same values = problems
Post by Pseudomonas_Torx on Dec 16th, 2010, 1:23pm
Hi Sir Raven.

Seit heute Nacht hat sich das Problem geklärt. Ich hab es jetzt doch noch geschafft den MS20 über Midi-OX und Midi-Yoke auf Kanal 16 umzurouten. Jetzt funzt alles so wie es soll.

Und das Problem war nicht das gewisse Daten an das andere Gerät durchgereicht werden, sondern dass beide Geräte auf dem selben Kanal an Live senden. Wenn ich nun ein Parameter zuweise, sendet der ja einen bestimmten Notenwert, dieser ist dann auch automatisch auf dem anderen Gerät zugewiesen, somit wird ja ein Gerät überflüssig.
Dank Midi-OX ist das aber zu regeln.

Thanks again to Peter, who has brought me to the idea of the routing.

Happy holidays yet.
Greetings Timo



MIDI-OX User Forum » Powered by YaBB 1 Gold - SP 1.3.1!