MIDI-OX User Forum (http://www.midiox.com/cgi-bin/yabb/YaBB.pl)
MIDI-OX >> MIDI-OX Bug List >> USB Hot unplug error
(Message started by: Peter L Jones on Apr 5th, 2003, 1:12pm)

Title: USB Hot unplug error
Post by Peter L Jones on Apr 5th, 2003, 1:12pm
Ooops -- I turned off my MK-249 and made MIDI-OX fall over:

(Normally this just works...)

MIDIOX caused a general protection fault
in module MIDIYOKE.DRV at 0001:0000079f.
Registers:
EAX=000009a4 CS=114f EIP=0000079f EFLGS=00000202
EBX=006f0000 SS=36ef ESP=00008972 EBP=00008980
ECX=0000003e DS=1147 ESI=00000000 FS=0fcf
EDX=00013ecf ES=0167 EDI=00000000 GS=0000
Bytes at CS:EIP:
8e 46 fe 26 8b 44 14 26 8b 54 16 8b f8 89 56 fa
Stack dump:
01670000 000009a4 00000000 899a3ecf 00000b68 0e3f0000 0167170a 00002ce0 00000000 00ef0000 009489b2 00000e97 00000000 00000000 003e0000 170a0000


MIDI OX Version 6.5.1.346
MIDI Yoke Junction Version 1.63
Win98

Title: Re: USB Hot unplug error
Post by Jamie OConnell on Apr 6th, 2003, 12:53pm
Yeah.  USB is very thorny, particularly on Windows 98.  I don't recommend hot-swapping devices while any MIDI applications are running (close the apps, turn on or off any USB devices, then relaunch).

Title: Re: USB Hot unplug error
Post by Peter L Jones on Apr 7th, 2003, 6:43pm
I was thinking about this.

I'm wrong - normally I tell MIDI OX to close the USB MIDI port before unplugging...

I'll remember for next time.

(Well, maybe I'll be inheritting my wife's P4 soon and Win98 will be quickly forgotten...)