MIDI-OX User Forum (http://www.midiox.com/cgi-bin/yabb/YaBB.pl)
MIDI-OX >> Questions and Discussion >> SysEx send problem
(Message started by: visua_lies on May 31st, 2002, 1:06pm)

Title: SysEx send problem
Post by visua_lies on May 31st, 2002, 1:06pm
Hello, I have a korg Z1 attached to my pc running win2000. I have a multiport USB midi patch bay (Midex 8 by Steinberg). I've been trying to send some new patches to the synth via midi-ox & indeed the process starts but hangs in the middle of the transfer. Midi-Ox pops up a message box that reads: "SysEx Output Devices: The port is transmitting data to the device. Wait until the data has been transmitted and then try again." I know the problem isnt w/the Korg since this issue also occurs when I have the Korg turned off. I suspect it's a problem w/my midi interface. Any help would be greatly appreciated. BTW I have tried increasing the buffer size & setting the delay to 60 ms.

Title: Re: SysEx send problem
Post by Jamie OConnell on May 31st, 2002, 9:56pm

on 05/31/02 at 13:06:58, visua_lies wrote:
"SysEx Output Devices: The port is transmitting data to the device. Wait until the data has been transmitted and then try again."


That message is indicative of too much SysEx being supplied to the MIDI interface too quickly (it's a busy signal).

Open View | SysEx... and then SysEx | Configure....  Ensure that [x] Delay after F7 is checked.  Try setting F7 buffer delay to 120ms.  If it starts working you can cut back on the delay somewhat.

Title: Re: SysEx send problem
Post by visua_lies on Jun 4th, 2002, 1:03pm
Jamie,

thanks alot for the suggestion. I basically did what you recommended except that I increased the F7 buffer delay size
to 200 & then it worked. Delay size of 120 was not quite enough. Again thanks for the assist, I can now transfer my patches to the synth again.



MIDI-OX User Forum » Powered by YaBB 1 Gold - SP 1.3.1!