Title: SysEx send problem Post by visua_lies on May 31st, 2002, 1:06pm Hello, I have a korg Z1 attached to my pc running win2000. I have a multiport USB midi patch bay (Midex 8 by Steinberg). I've been trying to send some new patches to the synth via midi-ox & indeed the process starts but hangs in the middle of the transfer. Midi-Ox pops up a message box that reads: "SysEx Output Devices: The port is transmitting data to the device. Wait until the data has been transmitted and then try again." I know the problem isnt w/the Korg since this issue also occurs when I have the Korg turned off. I suspect it's a problem w/my midi interface. Any help would be greatly appreciated. BTW I have tried increasing the buffer size & setting the delay to 60 ms. |
||
Title: Re: SysEx send problem Post by Jamie OConnell on May 31st, 2002, 9:56pm on 05/31/02 at 13:06:58, visua_lies wrote:
That message is indicative of too much SysEx being supplied to the MIDI interface too quickly (it's a busy signal). Open View | SysEx... and then SysEx | Configure.... Ensure that [x] Delay after F7 is checked. Try setting F7 buffer delay to 120ms. If it starts working you can cut back on the delay somewhat. |
||
Title: Re: SysEx send problem Post by visua_lies on Jun 4th, 2002, 1:03pm Jamie, thanks alot for the suggestion. I basically did what you recommended except that I increased the F7 buffer delay size to 200 & then it worked. Delay size of 120 was not quite enough. Again thanks for the assist, I can now transfer my patches to the synth again. |
||
MIDI-OX User Forum » Powered by YaBB 1 Gold - SP 1.3.1! YaBB © 2000-2003. All Rights Reserved. |