User Forum    :: Powered by YaBB
  « MIDI-OX User Forum - Data Mapping Sysex Handling »
Welcome, Guest. Please Login or Register.
Jun 19th, 2025, 11:34pm


Home Home Help Help Search Search Members Members Login Login Register Register


   MIDI-OX User Forum
   MIDI-OX
   Wish List
(Moderator: Jamie OConnell)
   Data Mapping Sysex Handling
« Previous topic | Next topic »
Pages: 1  Reply Reply Notify of replies Notify of replies Send Topic Send Topic Print Print
   Author  Topic: Data Mapping Sysex Handling  (Read 3394 times)
mrcomputer
New Member
*



MIDI-OX Rules!

   


Posts: 9
Data Mapping Sysex Handling
« on: Aug 27th, 2011, 3:04am »
Quote Quote Modify Modify

I am using the data mapping feature to send sysex and program change data.  If I paste entire string of data into the sysex windows then send, I see transmitted separate sysex strings WITH DELAY follow by any additional non-sysex data.  My wish is for the data mapping feature to process the data in the same way - including the delay.  The reason for the request is the keyboard processes the sysex (mode change), but cannot process the non-sysex program change data beause it has not had sufficient time to do the mode change.
 
TIA,
 
jbw
IP Logged
mrcomputer
New Member
*



MIDI-OX Rules!

   


Posts: 9
Re: Data Mapping Sysex Handling
« Reply #1 on: Jan 20th, 2012, 4:57am »
Quote Quote Modify Modify

bump
IP Logged
mrcomputer
New Member
*



MIDI-OX Rules!

   


Posts: 9
Re: Data Mapping Sysex Handling
« Reply #2 on: Feb 15th, 2012, 5:08am »
Quote Quote Modify Modify

bump!
IP Logged
4x4uk
Member
**



MIDI-OX Rules!

   


Posts: 48
Re: Data Mapping Sysex Handling
« Reply #3 on: Feb 15th, 2012, 7:18pm »
Quote Quote Modify Modify

bottom of the data map set up screen you can add a delay to the non sysex  data message
IP Logged
mrcomputer
New Member
*



MIDI-OX Rules!

   


Posts: 9
Re: Data Mapping Sysex Handling
« Reply #4 on: Feb 16th, 2012, 2:57pm »
Quote Quote Modify Modify

Not what I want.  That delay applies to the response time between midi event recognized and midi event sent.  I does not provide the F7 delay that is available if you use the sysex window.
So, to recap, what I want is the data mapping sysex output to respond as though I had pasted the string into the sysex view window (with a specified F7 delay time) and selected "send sysex".
IP Logged
mrcomputer
New Member
*



MIDI-OX Rules!

   


Posts: 9
Re: Data Mapping Sysex Handling
« Reply #5 on: Feb 16th, 2012, 3:10pm »
Quote Quote Modify Modify

Jamie,
 
Care to weigh in on this?  Wink
 
jbw
IP Logged
Pages: 1  Reply Reply Notify of replies Notify of replies Send Topic Send Topic Print Print

« Previous topic | Next topic »


MIDI-OX User Forum » Powered by YaBB 1 Gold - SP 1.3.1!